This is the latest recevied telemetry packets stored in our database for station/object DF9FP-5. If no packets are shown the sender has not sent any telemetry packets the latest 2 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Temp* | Humi* | Value3* | Value4* | Value5* |
---|---|---|---|---|---|
1732220044 | 24.3 deg C | 43.2 % | 0 | 0 | 0 |
1732219144 | 24.1 deg C | 43.4 % | 0 | 0 | 0 |
1732218244 | 23.9 deg C | 43.6 % | 0 | 0 | 0 |
1732217344 | 23.7 deg C | 43.7 % | 0 | 0 | 0 |
1732216444 | 23.5 deg C | 43.8 % | 0 | 0 | 0 |
1732215544 | 23.3 deg C | 43.8 % | 0 | 0 | 0 |
1732214644 | 23.2 deg C | 43.6 % | 0 | 0 | 0 |
1732214314 | 23.1 deg C | 43.5 % | 0 | 0 | 0 |
1732213414 | 23 deg C | 43.1 % | 0 | 0 | 0 |
1732212513 | 23 deg C | 43 % | 0 | 0 | 0 |
1732211613 | 23 deg C | 43 % | 0 | 0 | 0 |
1732210713 | 23 deg C | 43 % | 0 | 0 | 0 |
1732209813 | 23.1 deg C | 43 % | 0 | 0 | 0 |
1732208913 | 23 deg C | 43.1 % | 0 | 0 | 0 |
1732208013 | 23 deg C | 43.2 % | 0 | 0 | 0 |
1732207113 | 23 deg C | 43.3 % | 0 | 0 | 0 |
1732206213 | 22.9 deg C | 43.4 % | 0 | 0 | 0 |
1732205313 | 22.9 deg C | 43.8 % | 0 | 0 | 0 |
1732204413 | 22.7 deg C | 43 % | 0 | 0 | 0 |
1732203513 | 22.7 deg C | 42.9 % | 0 | 0 | 0 |
1732202613 | 22.7 deg C | 42.9 % | 0 | 0 | 0 |
1732202282 | 22.7 deg C | 42.8 % | 0 | 0 | 0 |
1732201382 | 22.7 deg C | 42.9 % | 0 | 0 | 0 |
1732200481 | 22.7 deg C | 42.9 % | 0 | 0 | 0 |
1732199581 | 22.7 deg C | 43.1 % | 0 | 0 | 0 |
*Used Equation Coefficients:
Temp: 0, 0.1, 0
Humi: 0, 0.1, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)