This is the latest recevied telemetry packets stored in our database for station/object DB0PIB. If no packets are shown the sender has not sent any telemetry packets the latest 2 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Vfm* | Vbuf* | Isol* | Ievs* | Tbat* |
---|---|---|---|---|---|
1737202182 | 13.3 V | 13.3 V | 5.08 A | 0 A | 5.5 C |
1737201888 | 13.3 V | 13.3 V | 5.27 A | 0 A | 5.5 C |
1737201882 | 13.3 V | 13.3 V | 5.27 A | 0 A | 5.5 C |
1737201582 | 13.4 V | 13.4 V | 7.03 A | 0 A | 5.5 C |
1737201283 | 13.1 V | 13.3 V | 7.23 A | 0 A | 5.5 C |
1737201282 | 13.1 V | 13.3 V | 7.23 A | 0 A | 5.5 C |
1737200982 | 13.3 V | 13.3 V | 6.25 A | 0 A | 5 C |
1737200709 | 13.3 V | 13.3 V | 5.66 A | 0 A | 5 C |
1737200682 | 13.3 V | 13.3 V | 5.66 A | 0 A | 5 C |
1737200382 | 13.4 V | 13.4 V | 7.23 A | 0 A | 5 C |
1737200084 | 13.5 V | 13.5 V | 8.79 A | 0 A | 5 C |
1737200082 | 13.5 V | 13.5 V | 8.79 A | 0 A | 5 C |
1737199782 | 13.6 V | 13.6 V | 11.52 A | -0.2 A | 5 C |
1737199522 | 13.6 V | 13.5 V | 11.52 A | -0.2 A | 5 C |
1737199482 | 13.6 V | 13.5 V | 11.52 A | -0.2 A | 5 C |
1737199182 | 13.4 V | 13.4 V | 10.74 A | 0 A | 5 C |
1737198883 | 12.8 V | 13 V | 7.03 A | 0 A | 5.5 C |
1737198882 | 12.8 V | 13 V | 7.03 A | 0 A | 5.5 C |
1737198582 | 12.9 V | 12.9 V | 3.52 A | 0 A | 5.5 C |
1737198294 | 12.9 V | 12.9 V | 3.32 A | 0 A | 5.5 C |
1737198282 | 12.9 V | 12.9 V | 3.32 A | 0 A | 5.5 C |
1737197982 | 12.8 V | 12.9 V | 2.93 A | 0 A | 5.5 C |
1737197720 | 12.8 V | 12.9 V | 2.73 A | 0 A | 5.5 C |
1737197682 | 12.8 V | 12.9 V | 2.73 A | 0 A | 5.5 C |
1737197382 | 12.9 V | 12.9 V | 3.12 A | 0 A | 5.5 C |
*Used Equation Coefficients:
Vfm: 0, 0.1, 0
Vbuf: 0, 0.1, 0
Isol: 0, 0.1953, -24.8031
Ievs: 0, 0.1953, -24.8031
Tbat: 0, 0.5, -64
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)