This is the latest recevied telemetry packets stored in our database for station/object SR8NZ. If no packets are shown the sender has not sent any telemetry packets the latest 2 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Rx1h* | Dg1h* | Eff1h* | A4* | A5* |
---|---|---|---|---|---|
1732259075 | 10 Pkt | 0 Pkt | 12 Pcnt | 0 None | 0 None |
1732255472 | 10 Pkt | 0 Pkt | 13 Pcnt | 0 None | 0 None |
1732251869 | 30 Pkt | 10 Pkt | 24 Pcnt | 0 None | 0 None |
1732248265 | 0 Pkt | 0 Pkt | 6 Pcnt | 0 None | 0 None |
1732244662 | 10 Pkt | 0 Pkt | 19 Pcnt | 0 None | 0 None |
1732241060 | 10 Pkt | 0 Pkt | 20 Pcnt | 0 None | 0 None |
1732230249 | 10 Pkt | 0 Pkt | 17 Pcnt | 0 None | 0 None |
1732226645 | 20 Pkt | 0 Pkt | 18 Pcnt | 0 None | 0 None |
1732223042 | 40 Pkt | 0 Pkt | 23 Pcnt | 0 None | 0 None |
1732219439 | 20 Pkt | 0 Pkt | 15 Pcnt | 0 None | 0 None |
1732215835 | 30 Pkt | 0 Pkt | 17 Pcnt | 0 None | 0 None |
1732212232 | 20 Pkt | 0 Pkt | 15 Pcnt | 0 None | 0 None |
1732205025 | 60 Pkt | 20 Pkt | 17 Pcnt | 0 None | 0 None |
1732201422 | 10 Pkt | 0 Pkt | 9 Pcnt | 0 None | 0 None |
1732197819 | 10 Pkt | 0 Pkt | 9 Pcnt | 0 None | 0 None |
1732194215 | 10 Pkt | 0 Pkt | 8 Pcnt | 0 None | 0 None |
1732190612 | 10 Pkt | 0 Pkt | 9 Pcnt | 0 None | 0 None |
1732187009 | 10 Pkt | 0 Pkt | 5 Pcnt | 0 None | 0 None |
1732183405 | 10 Pkt | 0 Pkt | 12 Pcnt | 0 None | 0 None |
1732179802 | 20 Pkt | 0 Pkt | 22 Pcnt | 0 None | 0 None |
1732176199 | 10 Pkt | 0 Pkt | 16 Pcnt | 0 None | 0 None |
1732172595 | 0 Pkt | 0 Pkt | 8 Pcnt | 0 None | 0 None |
1732168992 | 40 Pkt | 0 Pkt | 33 Pcnt | 0 None | 0 None |
1732165389 | 60 Pkt | 10 Pkt | 41 Pcnt | 0 None | 0 None |
1732161785 | 50 Pkt | 0 Pkt | 28 Pcnt | 0 None | 0 None |
*Used Equation Coefficients:
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
A4: 0, 0, 0
A5: 0, 0, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)