This is the latest recevied telemetry packets stored in our database for station/object LZ0DAP-13. If no packets are shown the sender has not sent any telemetry packets the latest 2 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Vin:* | Rx1h* | Dg1h* | EffTo* | Temp* |
---|---|---|---|---|---|
1732274750 | 14.32 Volt | 150 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732274150 | 14.32 Volt | 150 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732273550 | 14.32 Volt | 150 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732272950 | 14.32 Volt | 160 Pkt | 0 Pkt | 88 Pcnt | 25.28 C |
1732272350 | 14.32 Volt | 160 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732271750 | 14.32 Volt | 170 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732271150 | 14.32 Volt | 170 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732270550 | 14.32 Volt | 170 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732269950 | 14.32 Volt | 160 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732269350 | 14.32 Volt | 160 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732268750 | 14.32 Volt | 160 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732268150 | 14.32 Volt | 160 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732267550 | 14.32 Volt | 160 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732266950 | 14.32 Volt | 170 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732266351 | 14.32 Volt | 160 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732265750 | 14.32 Volt | 180 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732265151 | 14.32 Volt | 180 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732264551 | 14.32 Volt | 200 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732263951 | 14.32 Volt | 200 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732263351 | 14.32 Volt | 200 Pkt | 0 Pkt | 88 Pcnt | 25.58 C |
1732262751 | 14.32 Volt | 200 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732262151 | 14.32 Volt | 180 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732261551 | 14.32 Volt | 180 Pkt | 0 Pkt | 88 Pcnt | 25.28 C |
1732260951 | 14.32 Volt | 160 Pkt | 0 Pkt | 88 Pcnt | 25.43 C |
1732260351 | 14.32 Volt | 170 Pkt | 0 Pkt | 88 Pcnt | 25.28 C |
*Used Equation Coefficients:
Vin:: 0, 0.077, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
EffTo: 0, 1, 0
Temp: 0, 0.147, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)