This is the latest recevied telemetry packets stored in our database for station/object ED4ZAA-3. If no packets are shown the sender has not sent any telemetry packets the latest 2 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Vin* | Rx1h* | Dg1h* | Eff1h* | Temp* |
---|---|---|---|---|---|
1737255028 | 12.23 | 40 | 40 | 82 | -62 |
1737251425 | 12.23 | 50 | 40 | 71 | -62 |
1737247821 | 12.3 | 40 | 40 | 73 | -62 |
1737244218 | 12.3 | 70 | 60 | 80 | -62 |
1737237011 | 12.3 | 50 | 40 | 63 | -62 |
1737233408 | 12.38 | 50 | 50 | 71 | -62 |
1737229804 | 12.38 | 50 | 50 | 70 | -62 |
1737226201 | 12.38 | 40 | 40 | 63 | -62 |
1737222597 | 12.38 | 40 | 40 | 64 | -62 |
1737218994 | 12.45 | 50 | 50 | 69 | -62 |
1737215390 | 12.15 | 50 | 50 | 72 | -62 |
1737211787 | 13.95 | 40 | 40 | 63 | -62 |
1737208183 | 13.73 | 40 | 40 | 76 | -62 |
1737204580 | 13.73 | 40 | 40 | 66 | -62 |
1737200976 | 13.73 | 40 | 40 | 55 | -62 |
1737197373 | 14.18 | 40 | 40 | 56 | -62 |
1737193769 | 14.48 | 40 | 40 | 74 | -62 |
1737190166 | 14.25 | 50 | 40 | 52 | -62 |
1737186562 | 12.53 | 40 | 40 | 60 | -62 |
1737182959 | 12.15 | 40 | 40 | 79 | -62 |
1737179356 | 12.15 | 50 | 50 | 85 | -62 |
1737172149 | 12.15 | 40 | 40 | 73 | -62 |
1737168545 | 12.23 | 30 | 30 | 77 | -62 |
1737164942 | 12.23 | 40 | 40 | 91 | -62 |
1737161338 | 12.23 | 40 | 40 | 86 | -62 |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Temp: 0, 0.5, -62
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)